Biogas Pilot Plant - Overview

Standardized and customized biogas pilot facilities (BTP2) of the second generation for environmental sciences and biotechnology

BTP2 - the standard type

  • Glass reactor with different working volume
  • Continues operation with AUTO feeding (optional)
  • Electrical heating
  • Two level stirrer with gastight shaft
  • Dosage pumps for pH-control (Optional)
  • Gas bag to collect gas samples
  • Measurement equipment
    • Gas quantity
    • pH-value / Redox-potential (Optional) / Temperature
  • SENSOcontrol with touch panel

additional to the standard unit:

For advanced applications it is additionally possible to equip a Pilot Container:

  • Pilot container - fully equiped (air conditioned, miscellaneous electrical connection possibilities for pilot technologies, etc.)

To request more information and prices call + 49 351 88646-00 or e-mail us: info@uit-gmbh.de.

SENSOcontrol - Automation, Visualization and data logging of the Biogas Pilot Plants

  • Display of the actual values
  • Storage of data
  • Control / Readout of
    • Stirrer informations
    • measured values (gas quantity, ph-value,...)
    • Pump for pH-control (Optional)
    • Pump for feed and discharge (Optional)
  • Calibration support for sensors
  • Calculation of Nm³ of produced biogas
  • Touch panel functionality
  • Ethernet interface

BTP2 - the Standard Type

  • Glass reactor with different working volume
  • Continues operation with AUTO feeding (Optional)
  • Electrical heating
  • Two level stirrer with gastight shaft
  • Dosage pumps for pH-control (Optional)
  • Gas bag to collect gas samples
  • Measurement equipment
    • Gas quantity
    • pH-value / Redox-Potential  (Optional) / temperature
  • SENSOcontrol with touch panel

BTP2 Analyzer

  • Glass reactor with different working volume
  • Continues operation with AUTO feeding (Optional)
  • Electrical heating
  • Two level stirrer with gastight shaft
  • Dosage pumps for pH-control (Optional)
  • Gas bag to collect gas samples
  • Measurement equipment
    • Gas quantity
    • pH-value / Redox-Potential (Optional) / temperature
    • gas quality measurement system
  • SENSOcontrol with touch panel

BTP2 Control

  • up to 8 bioreactors on one gas quality measurement system
  • Glass reactor with different working volume
  • Continues operation with AUTO feeding (Optional)
  • Electrical heating
  • Two level stirrer with gastight shaft
  • Dosage pumps for pH-control (Optional)
  • Gas bag to collect gas samples
  • Measurement equipment
    • Gas quantity
    • pH-value / Redox-Potential (Optional) / temperature
    • gas quality measurement system
  • SENSOcontrol with touch panel

BTP2 Sterile

  • Bioreactor sterilisable
  • Glass reactor with different working volume
  • Electrical heating
  • Two level stirrer with gastight shaft
  • Dosage pumps for pH-control (Optional)
  • Gas bag to collect gas samples
  • Measurement equipment
    • Gas quantity
    • pH-Value / Redox-Potential (Optional) / temperature
    • gas quality measurement system
  • SENSOcontrol with touch panel

Pilot container

  • Container based fully equipped (air condition, electrical installation, etc.)
  • Bioreactor, stainless steel with different working volume
  • Automatically feed and discharge (Optional)
  • Electrical heating
  • Two level stirrer with gastight shaft
  • Dosage pumps for pH-control (Optional)
  • Gas bag to collect gas samples
  • Measurement equipment
    • Gas quantity
    • pH-Value / Redox-Potentail (Optional) / temperature
    • gas quality measurement system
  • SENSOcontrol with touch panel
                                            BTP2 Basic        BTP2 Standard BTP2 Analyzer   BTP2 Control    BTP2 Sterile    Pilot container

Reactor volumes

           
   2.5 / 6 liter
  •  
  •  
  •  
  •  
  •  
 
   15 / 20 / 30 / 60 liter
  •  
  •  
  •  
  •  

 

 
   200 / 1,500 liter          
  •  
   Electrical heating system incl. temperature controller
  •  
  •  
  •  
  •  
  •  
  •  
   Suitable to be sterilized        
  •  
 
Stirrer incl. gas-tight shaft feedthrough            
   Gas-tight shaft feedthrough
  •  
  •  
  •  
  •  
  •  
  •  
   Shaft feedthrough suitable to be sterilized        
  •  
 
   Stirrer suitable to operate asynchronous  
  •  
  •  
  •  
  •  
  •  
Measuring instrumentation            
   Gas quantity (gas drum counter or Milli gas counter)
  •  
  •  
  •  
  •  
  •  
  •  
   Automatic gas quality measurement (CH4, CO2, H2S, O2)    
  •  
  •  
  •  
  •  
      Use of measuring instrumentation for up to 8 reactor units      
  •  
 
  •  
      Measuring of H2 in gas phase    
  •  
  •  
 
  •  
   Air pressure sensor    
  •  
  •  
   
   pH-measurement in substrate
  •  
  •  
  •  
  •  
  •  
  •  
   ORP-measurement in substrate  
  •  
  •  
  •  
  •  
  •  
   Dissolved CO2 - measurement in substrate  
  •  
  •  
  •  
  •  
  •  
   Temperature in reactor
  •  
  •  
  •  
  •  
  •  
  •  
   Temperature of gas
  •  
  •  
  •  
  •  
  •  
  •  
   Speed and torque of stirrer
  •  
  •  
  •  
  •  
  •  
  •  
SENSOcontrol - data storage, visualization and control            
   SENSOcontrol incl. touch-display  
  •  
  •  
  •  
  •  
  •  
   pH-control - automatic pH-value setting  
  •  
  •  
  •  
  •  
  •  
   Automatic time-triggered feeding  
  •  
  •  
  •  
  •  
  •  
   Control of additional pumps  
  •  
  •  
  •  
  •  
  •  
  • Optional

Illustrations and descriptions may vary. The plant / product is subject to change depending on technical updates.

We will gladly give you an individual offer.

 

 

Anfrageformular



30.05.2017