Multi-Sensor-Module MSM-S2

The compact system for water quality monitoring with independent power supply for stationary monitoring of surface water and groundwater.

To request more information and prices call + 49 351 88646-00 or e-mail us: info@uit-gmbh.de.

  • Probe diameter 89 mm
  • External data logger LogTrans with remote data transfer
  • Detachable probe cable

Available parameters

  • pH-value / Redox potential (ORP)
  • Dissolved oxygen
  • Conductivity / Temperature
  • Pressure (water level)
  • Nitrate / Ammonium
  • Chloride
  • Bromide
  • Turbidity
  • Chlorophyll
  • Carbon dioxide
  • Data logger
  • Integrated remote transmission (GSM/GPRS) – option
  • Internal accumulator

Field of application

  • Stationary monitoring (Surface water, Ground water, Monitoring of piping networks)
  • Mobile application

Advantages

  • Wide range of available sensors
  • Up to 9 parameters can be measured simultaneously
  • Integrated data transmission technology
  • Parameter monitoring including optional alarm notification
Sensors - 6 Sensors plus pressure and temperature and ext. sensors configurable
  Absolute pressure sensor  800 ... 2,100 mbar; 800 ... 6,100 mbar; 800 ... 11,100 mbar
  Temperature sensor  0 °C ... 50 °C; resolution: 0.04 °C
  Conductivity sensor  0 ... 20 mS/cm; resolution 1 μS/cm
  pH  1 ... 14; resolution ΔpH = 0.01
  Redox potential  –2,000 ... +2,000 mV; resolution 1 mV
  pH/Redox – combination sensor  pH 1 ... 14; redox –2,000 ... +2,000 mV
  DO [O2] – luminescence  0... 40 mg/l O2, resolution 0.02 mg/l O2
  Turbidity  0 - 25/125/500/2500 NTU
  Ion selective sensors  Chloride, nitrate, ammonia and bromide – specification on request
  External sensors  Turbidity; chlorophyll
Technical data – MSM-S2 – Probe plus Data logger
  Dimensions  Measurement probe: diameter: 89 mm; length: 510 mm
  Material with medium contact  Stainless steel; POM; PUR, EPDM, NBR, PE plus sensor materials
  Data logger  LogTrans6-digi-GPRS or LogTrans 7-compact
  Probe cable  Cable Sheath PUR
  Operating temperature range  0°C ... 50°C probe; data logger -25°C ... +70°C

ffer.

 

 

Anfrageformular